PRODUCTS
Maximum Amperage: 15 | |
Cross Sectional Flow Area: .072 sq. in. | |
Maximum CFM: 15 | |
CFM | Max.Watts/linear in.of heated length |
1 | 100 |
2 | 100 |
4 | 100 |
6 | 150 |
8 | 200 |
10 | 250 |
15 | 375 |
Pressure Rating: 80 psig
Pressure Drop (psig)
Air Flow (SCFM)
Diameter: 5/8""
Length | Heated Length | Cat. No.w/o fittings | Cat. No. w/male |
---|---|---|---|
3″ | 2 1/2″ | AH62-3 | AH62-3-MF |
4″ | 3 1/2″ | AH62-4 | AH62-4-MF |
5″ | 4 1/2″ | AH62-5 | AH62-5-MF |
6″ | 5 1/2″ | AH62-6 | AH62-6-MF |
7″ | 6 1/2″ | AH62-7 | AH62-7-MF |
8″ | 7 1/2″ | AH62-8 | AH62-8-MF |
9″ | 8 1/2″ | AH62-9 | AH62-9-MF |
10″ | 9 1/2″ | AH62-10 | AH62-10-MF |
12″ | 11 1/2″ | AH62-12 | AH62-12-MF |
Red catalog number denotes stock item. See stock section for specific ratings.
MF: 1/2″ NPT male fittings (add MF to catalog number).
FF: 1/4″ NPT female fittings (add FF to catalog number).
HF: Hose adaptor on entry end only (add HF to catalog number and specify I.D. of hose).
SF-28: Three Phase
SF-29: Multiple Heat circuits – Specify wattages