PRODUCTS
U.L. Recognized – E56973
C.S.A. Certified – 016386-0-000
Lengths between or longer than those listed may be ordered.
Size: 1/8″ x 1/8″ (.124/.210 x .124/.120) | |||
Maximum Amperage: 1 Not UL/CSA |
Sheath | Cat.No. | Min. | Max. |
---|---|---|---|
1″ | SS12-1 | 10 | 15 |
2″ | SS12-2 | 10 | 35 |
3″ | SS12-3 | 10 | 55 |
4″ | SS12-4 | 10 | 75 |
5″ | SS12-5 | 10 | 95 |
6″ | SS12-6 | 10 | 115 |
7″ | SS12-7 | 10 | 135 |
8″ | SS12-8 | 10 | 155 |
9″ | SS12-9 | 10 | 175 |
10″ | SS12-10 | 10 | 195 |
11″ | SS12-11 | 10 | 215 |
12″ | SS12-12 | 10 | 235 |
For longer lengths, compute wattage at: 10 watts per linear 1/2″ |
Size: 1/4″ (.249/.245 x .249/.245) | 3/8″ (.374/.370 x .374/.370) | 1/2″ (.499/.495 x .499/.495) | |||||||
Maximum Amperage: 3.5 | 6 | 10 |
Sheath | Cat.No. | Min. | Max. | Cat.No. | Min. | Max. | Cat.No. | Min. | Max. |
---|---|---|---|---|---|---|---|---|---|
2″ | SS25-2 | 10 | 60 | SS37-2 | 10 | 90 | SS50-2 | 10 | 130 |
3″ | SS25-3 | 10 | 100 | SS37-3 | 10 | 150 | SS50-3 | 10 | 210 |
4″ | SS25-4 | 10 | 150 | SS37-4 | 10 | 210 | SS50-4 | 10 | 300 |
6″ | SS25-6 | 10 | 225 | SS37-6 | 10 | 330 | SS50-6 | 10 | 500 |
8″ | SS25-8 | 10 | 350 | SS37-8 | 10 | 450 | SS50-8 | 10 | 700 |
10″ | SS25-10 | 10 | 450 | SS37-10 | 10 | 570 | SS50-10 | 10 | 850 |
12″ | SS25-12 | 10 | 550 | SS37-12 | 10 | 690 | SS50-12 | 10 | 1000 |
16″ | SS25-16 | 10 | 750 | SS37-16 | 10 | 930 | SS50-16 | 10 | 1280 |
18″ | SS25-18 | 10 | 840 | SS37-18 | 10 | 1050 | SS50-18 | 10 | 1440 |
24″ | SS25-24 | 10 | 840 | SS37-24 | 10 | 1410 | SS50-24 | 10 | 1920 |
For longer lengths, compute wattage at: |
Minimum Wattage
The following table should be used to determine the allowable voltage for low wattage miniature elements:
Size: | 1/8″ Square | 3/16″ Square | ||||||
---|---|---|---|---|---|---|---|---|
Length | 30v | 60v | 120v | 230v | 30v | 60v | 120v | 230v |
1″ | .6w | 2.5w | 10w | NA | .8w | 3w | 12w | NA |
1 1/2″ | .6w | 2.5w | 10w | NA | .5w | 2w | 8w | 30w |
2″ | .5w | 2w | 8w | 27w | .4w | 1.5w | 6w | 22w |
NA – Not Available
Standard voltage is either 120V or 240V. Other voltages are available.
All units within published amperage limits, are manufactured with 6″ (type SF1) leads; longer length leads are available. Standard insulation on 1/4″ square units is Teflon (200°C). Fiberglass (250°C) is standard on all other sizes.
Lengths between or longer than those listed may be ordered.
Size: 1/8″ x 1/4″ (.124/.120 x 249/.245) | 1/8″ x 3/8″ (.124/.120 x .374 /.370) | |||||
Maximum Amperage: 2 | 3.5 |
Sheath | Cat.No. | Min. | Max. | Cat.No. | Min. | Max. |
---|---|---|---|---|---|---|
1″ | SR14-1 | 10 | 20 | SR13-1 | 10 | 35 |
2″ | SR14-2 | 10 | 55 | SR13-2 | 10 | 90 |
3″ | SR14-3 | 10 | 85 | SR13-3 | 10 | 140 |
4″ | SR14-4 | 10 | 110 | SR13-4 | 10 | 190 |
5″ | SR14-5 | 10 | 135 | SR13-5 | 10 | 240 |
6″ | SR14-6 | 10 | 170 | SR13-6 | 10 | 290 |
7″ | SR14-7 | 10 | 200 | SR13-7 | 10 | 340 |
8″ | SR14-8 | 10 | 230 | SR13-8 | 10 | 390 |
9″ | SR14-9 | 10 | 260 | SR13-9 | 10 | 440 |
10″ | SR14-10 | 10 | 290 | SR13-10 | 10 | 490 |
11″ | SR14-11 | 10 | 320 | SR13-11 | 10 | 540 |
12″ | SR14-12 | 10 | 350 | SR13-12 | 10 | 590 |
For longer lengths, compute wattage at: 15 watts per linear 1/2″ 25 watts per linear 1/2″ |
Lengths between or longer than those listed may be ordered.
Size: 1/4″ x 5/8″ (.249/.245 X .624/.620) | 1/4″ x 1″ (.249/.245 X .999/993) | |||||
Maximum Amperage: 6 | 10 |
Sheath | Cat.No. | Min. | Max. | Cat.No. | Min. | Max. |
---|---|---|---|---|---|---|
1″ | SR15-1 | 10 | 35 | SR16-1 | 10 | 50 |
2″ | SR15-2 | 10 | 100 | SR16-2 | 10 | 150 |
3′ | SR15-3 | 10 | 175 | SR16-3 | 10 | 300 |
4″ | SR15-4 | 10 | 250 | SR16-4 | 10 | 400 |
5″ | SR15-5 | 10 | 320 | SR16-5 | 10 | 500 |
6″ | SR15-6 | 10 | 455 | SR16-6 | 10 | 600 |
7″ | SR15-7 | 10 | 560 | SR16-7 | 10 | 700 |
8″ | SR15-8 | 10 | 640 | SR16-8 | 10 | 800 |
9″ | SR15-9 | 10 | 720 | SR16-9 | 10 | 900 |
10″ | SR15-10 | 10 | 800 | SR16-10 | 10 | 1000 |
11″ | SR15-11 | 10 | 880 | SR16-11 | 10 | 1100 |
12″ | SR15-12 | 10 | 960 | SR16-12 | 10 | 1200 |
16″ | SR15-16 | 10 | 1280 | SR16-16 | 10 | 1600 |
18″ | SR15-18 | 10 | 1440 | SR16-18 | 10 | 1800 |
24″ | SR15-24 | 10 | 1440 | SR16-24 | 10 | 2400 |
For longer lengths, compute wattage at: 35 watts per linear 1/2″ 50 watts per linear 1/2″ |
Wattage tolerances are held to +5%, -105 at rated voltage. Width and height are always .001″ less but not more than .010″ less than the nominal (fractional) heater size; length tolerances are ±2% with a ±1/16″ minimum. This sizing is maintained so that all units are a slide fit into a standard milled slot of the size required. Thermal action will expand the unit to a snug fit for best heat conduction. To avoid early burn out, review our article on extending heater life.
After determining the wattage required and the line voltage available, determine the physical space available for heaters and the numbers of heaters required. Review Special Features.
Specify: catalog number, wattage, voltage, lead length, and special features required.
Example: SR16-7.5/750W/240V/SF1-48.