PRODUCTS
Maximum Amperage: 20 | |||
Cross Sectional Flow Area: .152 sq. in. |
Sizes:Length | Heated Length | Catalog No. | Wattage |
---|---|---|---|
6″ | 4″ | PFO-6 | 600 |
8″ | 6″ | PFO-8 | 900 |
10″ | 8″ | PFO-10 | 1200 |
12″ | 10″ | PFO-12 | 1500 |
18″ | 16″ | PFO-18 | 2400 |
Red catalog number denotes stock item. See stock section for specific ratings.
Above wattages are based on 50 watts per square inch for use with water at low flow.Higher flow rates and/or different liquids will effect allowable watt densities. Consult factory.
Sizes between those listed and larger in diameter are available. Consult factory.
Thermocouple mounting fitting is available for use with the standard miniature circulation heater.The fitting is threaded into the exit end as shown below. Specify TC-5 fitting.
* Thermistor adapter and catalog number TH-1 must be used for thermistor probe mounting in the TC5 fitting.
L Dim | Catalog Number | K.W. | Volts | Line Amps | Phase |
---|---|---|---|---|---|
8 | WB1511 | 1.5 | 120 | 12.5 | 1 |
8 | WB1521 | 1.5 | 208 | 7.2 | 1 |
8 | WB1541 | 1.5 | 240 | 6.3 | 1 |
12 | WB3011 | 3 | 120 | 25.0 | 1 |
12 | WB3021 | 3 | 208 | 14.4 | 1 |
12 | WB3041 | 3 | 240 | 12.5 | 1 |
14 | WB4021 | 4 | 208 | 19.2 | 1 |
14 | WB4041 | 4 | 240 | 16.7 | 1 |
14 | WB4051 | 4 | 480 | 8.3 | 1 |
18 | WB5021 | 5 | 208 | 24.0 | 1 |
18 | WB5041 | 5 | 240 | 20.8 | 1 |
18 | WB5051 | 5 | 480 | 10.4 | 1 |
18 | WB5023 | 5 | 208 | 13.9 | 3 |
18 | WB5043 | 5 | 240 | 12.0 | 3 |
18 | WB5053 | 5 | 480 | 6.0 | 3 |
22 | WB7023 | 7 | 208 | 19.4 | 3 |
22 | WB7043 | 7 | 240 | 16.8 | 3 |
22 | WB7053 | 7 | 480 | 8.4 | 3 |
Specify Catalog Number from table above.